Main components |
Technique parameter of x ray equipment price |
IMD X-ray tube |
Model:MSLCX06 x-ray machine
|
Model:MSLCX05 x-ray machine
|
Power:3.5kW |
Power:5.0kW |
Double focus fixed anode focus: |
Double focus rotational anode focus: |
1.5mm / 0.6mm |
0.3mm / 0.6mm |
Anode Heat Capacity: |
Anode Heat Capacity:200kHu X-ray tube |
40kHu X-ray tube sleeve |
sleeve heat capacity:800kHu |
heat capacity:667kHu |
|
High Voltage X-ray |
Working frequency:40kHz |
Generator |
Image intensifier |
Toshiba 9"(including 3 fields of view 4.5"/ 6"/9") |
Tube voltage |
Fluoroscopy Radiograph: |
Fluoroscopy Radiograph:40kV-120kV |
40kV-110kV |
Tube current |
Fluoroscopy: 0.5-4mA Enhanced Automatic Fluoroscopy: 1mA-8mA |
Pulse Fluoroscopy :2pps;8mA |
mAs |
1mA.s-250mA.S |
Fluoroscopy mode |
Manual Fluoroscopy; Semi-Automatic Fluoroscopy;Automatic Fluoroscopy; |
Enhanced Automatic Fluoroscopy; Pulse Fluoroscopy |
Intelligent exposure |
No matter the object is in the center or on the fringing field of the image |
control |
intensifier, the images are the same. The exposure dose is reduced. |
Iris beam limiting |
when not exposure, keep in the state of Iris Beam limiting preview ,when |
device |
exposure, keep blanking cycle track |
General radiography |
40kV-120kV;1.0mA.s-250mA.s |
step length 1 kV;1.0mA.s |
Digital radiography |
40kV-120kV;Max 16mA |
Common screen film radiography is |
(digital spot film) |
eliminated. Digital radiography can get |
|
better images |
C-arm machinery |
C-arm stander(with perfect C arm balance system) of ultra-quiet motor-driven |
index |
up and down, easy and handy to operate. The machine can maintain balance |
|
with up and down of the C arm. |
|
Distance between focus and window>900mm, arc depth>650mm, horizontal |
|
moving range :200mm vertical moving range:400mm |
|
Tilt angle :±12.5° rotation :±180°corner:125°(-35°– +90°) |
Laser Orientation |
Laser positioning function can help to position precisely and reduce exposure |
times in the operation, reduce unnecessary radiation. |
Radiography mode |
Image intensifier & Real-time digital image(1.3 million pixel) processing system |
(CCD)Digital video |
million pixels high-definition, high-speed CCD camera, a 1024 × 1024 matrix, |
camera |
30 frames per second image acquisition, through real-time adjustment of |
|
window width, window level, noise reduction, sharpening and Gain adjustment |
|
to ensure high-quality and high-resolution images. |
Image resolution |
Grey level:10 Resolution:22 lp/cm |
index |
Camera virtual rotation design |
No X-ray needed, also called digital image rotation,display |
the right angle when exposure, superior to camera mechanical rotation |
Image processing system |
1.Real time edge enhancement |
Image sharpening is also called |
(sharpening) |
edge enhancement, that is, to make |
|
blurry edge of the image clearer |
2.Real time adjustment of the |
Obtain images by real-time adjustment |
window width and window level |
of window width,window level, displaying |
|
images with different brightness. |
3.Real time(static)multiform |
Noise reduction, and improve image clarity |
noise reduction |
4.Real tim GAIN adjustment |
Can amplify image signal, reduce x-ray |
dose, suitable for patient with super large size. |
5.Real tim dynamic brightness |
Through dynamic logarithmic transformation, |
compensation and R calibration |
linear reduction the system signals and r |
functions |
calibration technology, dark parts of the image |
|
can be enhanced and clear rich-layer images |
|
can be obtained |
6.Image conversing ,up-down and right-left rotating,and frame freezing |
7.Patient information management ,Clinic report and print |
8.The Image can be storage as JPG and DICOM 3.0 format, can be linked |
to hard-disk , |
USB and DVD and printer,meet the need of sharing the network information , |
communication and storage in hospital |
Display |
Display2 17"TFT-LCD display |
Printer |
Printer Laser / jet Printer |
Standard |
1.Combined tube(5.0kW)IMD |
1 set; |
configuration |
2.Image intensifier (9 inch 3 fields of view) Toshiba |
1 set |
|
3.C-arm stander (with full C-arm balance system) |
1 set; |