Anesthesia & Ventilator | Patient Monitor | Autoclaves & Sterilizers | ECG & EKG | Incubator | Veterinary equipment | Infusion & Syringe Pump | Dental Instrument | Mortuary Equipment | Medical Furniture | Centrifuge | Disabled Equipment | Ungrouped | Body Analyzers | Ultrasound | X-ray machine | Blood & Urine Analyzer | www.e-healthmachine.com

Medical supplies wholesale c-arm x-ray machine (MSLCX05-G)

Properties:x-ray machine
Brand Name:MK
Model Number:MKCX05-G
Place of Origin:Guangdong, China (Mainland)
Item:X-ray machine
Type:C-arm x-ray machine
Supply:Directly from factory
out looking::mobile & c-arm
mAs:1mA.s-250mA.S
Quality:With CE proved
Fluoroscopy Radiograph:40 kV-120kV
Power:5 kw
Working frequency:40 kHz
Resolution:22 lp/cm

Medical supplies wholesale c-arm x-ray machine (MSLCX05-G)

 

Product Description
This x-ray machine with rotating anode x-ray tube

 

                                  

Main components Technique parameter of x ray equipment price
IMD X-ray tube Model:MSLCX06 x-ray machine
Model:MSLCX05 x-ray machine
Power:3.5kW Power:5.0kW
Double focus fixed anode focus: Double focus rotational anode focus: 
1.5mm / 0.6mm 0.3mm / 0.6mm
Anode Heat Capacity: Anode Heat Capacity:200kHu X-ray tube 
40kHu X-ray tube sleeve sleeve heat capacity:800kHu
heat capacity:667kHu  
High Voltage X-ray Working frequency:40kHz
Generator
Image intensifier Toshiba 9"(including 3 fields of view 4.5"/ 6"/9")
Tube voltage Fluoroscopy Radiograph: Fluoroscopy Radiograph:40kV-120kV
40kV-110kV
Tube current Fluoroscopy: 0.5-4mA  Enhanced  Automatic Fluoroscopy: 1mA-8mA    
Pulse  Fluoroscopy :2pps;8mA
mAs 1mA.s-250mA.S
Fluoroscopy  mode Manual  Fluoroscopy; Semi-Automatic Fluoroscopy;Automatic Fluoroscopy;
 Enhanced  Automatic Fluoroscopy; Pulse  Fluoroscopy
Intelligent exposure No matter the object is in the center or on the fringing field of the image 
control intensifier, the images are the same. The exposure dose is reduced.
Iris beam limiting when not exposure, keep in the state of Iris Beam limiting preview ,when
device  exposure, keep blanking cycle track
General radiography 40kV-120kV;1.0mA.s-250mA.s step length 1 kV;1.0mA.s
Digital radiography 40kV-120kV;Max 16mA Common screen film radiography is 
(digital spot film) eliminated. Digital radiography can get 
  better images
C-arm machinery C-arm stander(with perfect C arm balance system) of ultra-quiet motor-driven
index  up and down, easy and handy to operate. The machine can maintain balance
   with up and down of the C arm.
  Distance between focus and window>900mm, arc depth>650mm, horizontal 
  moving range :200mm vertical moving range:400mm
  Tilt angle :±12.5°  rotation :±180°corner:125°(-35°– +90°)
Laser Orientation Laser positioning function can help to position precisely and reduce exposure
 times in the operation, reduce unnecessary radiation.
Radiography mode
Image intensifier & Real-time digital image(1.3 million pixel) processing system
(CCD)Digital video   million pixels high-definition, high-speed CCD camera, a 1024 × 1024 matrix, 
camera 30 frames per second image acquisition, through real-time adjustment of 
  window width, window level, noise reduction, sharpening and Gain adjustment
   to ensure high-quality and high-resolution images.
Image  resolution   Grey level:10  Resolution:22 lp/cm
index
Camera virtual rotation design No X-ray needed, also called digital image rotation,display 
the right angle when exposure, superior to camera  mechanical  rotation
Image processing system 1.Real time edge  enhancement Image sharpening is also called 
(sharpening) edge enhancement, that is, to make 
   blurry edge of the image clearer
2.Real time adjustment of the  Obtain images by real-time adjustment 
window width and window level of window width,window level, displaying
  images with different brightness.
3.Real time(static)multiform  Noise reduction, and improve image clarity
noise reduction
4.Real tim GAIN adjustment Can amplify image signal, reduce x-ray 
dose, suitable for patient with super large size.
5.Real tim dynamic brightness  Through dynamic logarithmic transformation,
compensation and R calibration linear reduction the system signals and r 
 functions calibration technology, dark parts of the image
   can be enhanced and clear rich-layer images
   can be obtained
6.Image conversing ,up-down and right-left rotating,and frame freezing
7.Patient information management ,Clinic report  and print
8.The Image can be storage as JPG and DICOM 3.0 format, can be linked 
to hard-disk ,
USB  and DVD and printer,meet the need of sharing the network information ,
communication  and  storage  in   hospital
Display Display2 17"TFT-LCD display
Printer Printer Laser / jet Printer
Standard  1.Combined tube(5.0kW)IMD 1 set;
configuration 2.Image intensifier (9 inch 3 fields of view) Toshiba 1 set
  3.C-arm stander (with full C-arm balance system) 1 set;

 

 