Anesthesia & Ventilator | Patient Monitor | Autoclaves & Sterilizers | ECG & EKG | Incubator | Veterinary equipment | Infusion & Syringe Pump | Dental Instrument | Mortuary Equipment | Medical Furniture | Centrifuge | Disabled Equipment | Ungrouped | Body Analyzers | Ultrasound | X-ray machine | Blood & Urine Analyzer | www.e-healthmachine.com

Double channel portable blood coagulation/chemistry analyzer (MSLBA12-G)

Type:Biochemical Analysis System
Brand Name:MK
Model Number:MKBA12-G
Place of Origin:Guangdong, China (Mainland)
Item:blood chemistry analyzer
Warranty:30-360 days
Delivery:fasted delivery
Incubator Temperature:37±0.2°C
Repeatability:CV≤5%
Power:≤80W
Other information:double channer
Reagent:Open reagents
Connecting:PC connecting
Pdf file:email agatha@medicalequipment- msl.com

 

 

 

Double channel portable blood coagulation/chemistry analyzer(MSLBA12-G)

 

 

 

 

Product Description

 

 

Specifications

We are professional supplier specialized in all kind of blood analyzers.
Double channel portable blood coagulation/chemistry analyzer(MSLBA12-G)

 

 

 

 
 
Blood coagulation/chemistry analyzer
Test Method:Dispersion light nephelometric analysis
Test Principle:The highest point on first order differentiation,Percentage analysis
Zero point correction:auto track the zero point,eliminate the interference of sample and reagent
Wavelength:470nm
Light Source:Cold Lamp with high brightness and long lifetime
Detector:unique Dispersion light detector with high sensitivity and repeatability,immunized the effect
on result of jaundice,hemolysis,chyle and turbidity on plasma
Test Channel:each channel is independent,one or more,same or different items can be tested
Simultaneously
Incubator:Provide reagent and sample with stable incubator,
Incubator Temperature:37±0.2°C
Measure trigger:Auto trigger the measurement through configured pipette
Item modify:easy to add or edit items,easy to set the items parameters
Calibration:single-point calibration; multipoint calibration; auto store and match with calibration curve
Quality control:auto draw the quality figure
Reagent:Open reagent system
Reagent volume:≤40μL
Sample volume:≤40μL
Memory:Save more than 10000 samples results,and auto recovering the results when power is off during working .
Repeatability:CV≤5%
Calculative item:S,%,PTR,INR,Fib can be get through PT,This leads to lower the cost of reagent
Printer:Inner thermal printer,can be connected to external printer
Information edit:easy to input and edit the detail information of patients
Interface:RS-232 serial port,can be connected to external printer and computer
Working Environment:Temperature 10°C~30°C Humidity ≤70%RH
Voltage:85-264V,Auto adapt according to the input voltage
Power:≤80W
Quality System:Recognized by CE,TUV and CMD.
Test Items
PT APTT TT Fib RepT VT AT-Ⅲ Protein-S Protein-C LA Hep
 

 

How to update software

If you need update the software of the blood coagulation/chemistry analyzer,Please refer to the burn program method to fix the software you need and connection programmer well, then in accordance with the requirements of the program updates to update the software for main MPU and Auxiliary MPU.

Attention: when you burn LM3S5B91 program,connect J18. When you burn LM3S611 program, connect J8.

Maintenance

Routine Maintenance

(1) Avoiding instrument heating system is always in the heating state when the instrument is free for long time, please power off the instrument .
(2) Avoiding dust or sundry fall into measurement channels and affecting the measurement result, please cover the measurement channels when the instrument is free.
Trouble and Handle-Each working point voltage detection
Each working point voltage and circuit unit as shown as table-1: 
Table-1:coagulator voltage detecting point comparison table
NO./Detecting point/Voltage/Function/explanation
1.TP1/+12V/Supply for heating block./If abnormal,the instrument can not heat normally.
2.TP2/+5V/Supply for printer./If abnormal,it will can not print and detect the printer paper.
3.TP3/+12V/Supply for heating block./If abnormal,the instrument will can not heat normally.
4.TP4/+2.5V/External reference voltage for U17(ADS1259)./There is no need to detect this point’s voltage except  solder U12.
5.TP5/+3.3V/Supply for 3.3V digital circuit./If abnormal,the instrument will can not start.
6.TP6/+1.2VA/Supply for temperature correction circuit./If abnormal,it will affect the temperature control.
7.TP7/-1.2VA/Supply for temperature correction circuit./If abnormal,it will affect the temperature control.
8.TP8/-8VA/Supply for Analog circuit./If abnormal,it will affect AD collection.
9.TP9/-5VA/Supply for -1.2V Level conversion circuit./If abnormal,it will affect the temperature control.
10.TP10/+5V/Supply for display and digital circuit pull-up voltage./If abnormal,the instrument will can not start.
11.TP11/-12VA/Supply for screen contrast circuit,-8VA,-5VA conversion circuit./If abnormal,it will affect display,AD collection and temperature control.
12.TP12/+12VA/Supply for screen contrast circuit,-8VA,-5VA conversion circuit./If abnormal,it will affect display,AD collection and temperature control.
13.TP13/+5VA/Supply for -1.2V conversion circuit and temperature control circuit./If abnormal,it will affect temperature control.
14.TP14/+8VA/Supply for analog circuit./If abnormal,it will affect display and AD collection.
 
 

Blood coagulation/chemistry analyzer maintenance manual overview
Blood chemistry analyzer structure introduction (MSLBA12-G)

 

Block diagram for blood coagulation/chemistry analyzer

 

System component A for blood coagulation/chemistry analyzer

System component B for blood coagulation/chemistry analyzer

 


 

 

 

 

Welcome to email us via agatha(at)medicalequipment-msl.com

for double channel portable blood coagulation/chemistry analyzer (MSLBA12-G) !!

 

 

 

 

Have any question, Please enter the form below and click the submit button.


*
*
*
0 + 4 = ?
Please enter the answer to the sum & Click Submit to verify your registration.
CATEGORY AND TAGS:

Blood & Urine Analyzer

Related Items